Possible malfunction on local adapter错误,无法判断到底故障出在哪里,请求帮助
我们有三台小机,两台做的HA,另一台做了两个逻辑分区,也做成了HA,在某一天的同一时间都出现了一次这个错误
173C787F 1120013111 I S topsvcs Possible malfunction on local adapter
173C787F 1120013111 I S topsvcs Possible malfunction on local adapter
其中生产(串口心跳)的系统就被了这两个错误就没有其它的了。
但是另外那个两个逻辑分区的小机(IP心跳)就报的错误比较多了,其中一个逻辑分区的系统还重新启动了。
A6DF45AA 1120014111 I O RMCdaemon The daemon is started.
67145A39 1120014011 U S SYSDUMP SYSTEM DUMP
A6D1BD62 1120014011 I H unspecified Firmware Event
A6D1BD62 1120014011 I H unspecified Firmware Event
A6D1BD62 1120014011 I H unspecified Firmware Event
A6D1BD62 1120014011 I H unspecified Firmware Event
A6D1BD62 1120014011 I H unspecified Firmware Event
F48137AC 1120014011 U O minidump COMPRESSED MINIMAL DUMP
BC3BE5A3 1120014011 P S SRC SOFTWARE PROGRAM ERROR
9DBCFDEE 1120014111 T O errdemon ERROR LOGGING TURNED ON
DB14100E 1120013311 P U LIBLVM Group Services detected a failure
AA8AB241 1120013311 T O clstrmgrES OPERATOR NOTIFICATION
12081DC6 1120013311 P S haemd SOFTWARE PROGRAM ERROR
9DEC29E1 1120013311 P O grpsvcs Group Services daemon exit to merge doma
FE2DEE00 1120013311 P S SYSXAIXIF DUPLICATE IP ADDRESS DETECTED IN THE NET
FE2DEE00 1120013311 P S SYSXAIXIF DUPLICATE IP ADDRESS DETECTED IN THE NET
AB59ABFF 1120013311 U U LIBLVM Remote node Concurrent Volume Group fail
AB59ABFF 1120013311 U U LIBLVM Remote node Concurrent Volume Group fail
AB59ABFF 1120013311 U U LIBLVM Remote node Concurrent Volume Group fail
AB59ABFF 1120013311 U U LIBLVM Remote node Concurrent Volume Group fail
AB59ABFF 1120013311 U U LIBLVM Remote node Concurrent Volume Group fail
AB59ABFF 1120013311 U U LIBLVM Remote node Concurrent Volume Group fail
173C787F 1120013311 I S topsvcs Possible malfunction on local adapter
173C787F 1120013311 I S topsvcs Possible malfunction on local adapter
如果是系统的问题,但是三台小机同时出现的问题的可能性不大吧,感觉还是硬件的问题
问过机房他们说网络和电源都没问题。我此时不知道如何判断
173C787F 1120013111 I S topsvcs Possible malfunction on local adapter
173C787F 1120013111 I S topsvcs Possible malfunction on local adapter
其中生产(串口心跳)的系统就被了这两个错误就没有其它的了。
但是另外那个两个逻辑分区的小机(IP心跳)就报的错误比较多了,其中一个逻辑分区的系统还重新启动了。
A6DF45AA 1120014111 I O RMCdaemon The daemon is started.
67145A39 1120014011 U S SYSDUMP SYSTEM DUMP
A6D1BD62 1120014011 I H unspecified Firmware Event
A6D1BD62 1120014011 I H unspecified Firmware Event
A6D1BD62 1120014011 I H unspecified Firmware Event
A6D1BD62 1120014011 I H unspecified Firmware Event
A6D1BD62 1120014011 I H unspecified Firmware Event
F48137AC 1120014011 U O minidump COMPRESSED MINIMAL DUMP
BC3BE5A3 1120014011 P S SRC SOFTWARE PROGRAM ERROR
9DBCFDEE 1120014111 T O errdemon ERROR LOGGING TURNED ON
DB14100E 1120013311 P U LIBLVM Group Services detected a failure
AA8AB241 1120013311 T O clstrmgrES OPERATOR NOTIFICATION
12081DC6 1120013311 P S haemd SOFTWARE PROGRAM ERROR
9DEC29E1 1120013311 P O grpsvcs Group Services daemon exit to merge doma
FE2DEE00 1120013311 P S SYSXAIXIF DUPLICATE IP ADDRESS DETECTED IN THE NET
FE2DEE00 1120013311 P S SYSXAIXIF DUPLICATE IP ADDRESS DETECTED IN THE NET
AB59ABFF 1120013311 U U LIBLVM Remote node Concurrent Volume Group fail
AB59ABFF 1120013311 U U LIBLVM Remote node Concurrent Volume Group fail
AB59ABFF 1120013311 U U LIBLVM Remote node Concurrent Volume Group fail
AB59ABFF 1120013311 U U LIBLVM Remote node Concurrent Volume Group fail
AB59ABFF 1120013311 U U LIBLVM Remote node Concurrent Volume Group fail
AB59ABFF 1120013311 U U LIBLVM Remote node Concurrent Volume Group fail
173C787F 1120013311 I S topsvcs Possible malfunction on local adapter
173C787F 1120013311 I S topsvcs Possible malfunction on local adapter
如果是系统的问题,但是三台小机同时出现的问题的可能性不大吧,感觉还是硬件的问题
问过机房他们说网络和电源都没问题。我此时不知道如何判断
作者: 东北胖子 发布时间: 2011-12-08
173C787F 1120013111 I S topsvcs Possible malfunction on local adapter
173C787F 1120013111 I S topsvcs Possible malfunction on local adapter
详细信息,这几台小机错误信息格式都是一样的,最先出现的是192.168.0 IP段的网卡错误,然后是对外访问IP的错误,信息如下:
---------------------------------------------------------------------------
LABEL: TS_LOC_DOWN_ST
IDENTIFIER: 173C787F
Date/Time: Sun Nov 20 01:31:35 BEIST 2011
Sequence Number: xxxx
Machine Id: 0000FACDD600
Node Id: xxxxx
Class: S
Type: INFO
Resource Name: topsvcs
Description
Possible malfunction on local adapter
Probable Causes
Local adapter mal-functioned
Local adapter lost connection to network
Local adapter mis-configured
Failure Causes
Local adapter mal-functioned
Local adapter lost connection to network
Local adapter mis-configured
Recommended Actions
Verify adapter configuration
Verify network connectivity
Detail Data
DETECTING MODULE
rsct,nim_control.C,1.39.1.18,4961
ERROR ID
6zV5DL.rTylC/ZDO1A2.e.1...................
REFERENCE CODE
Adapter interface name
en2
Adapter offset
0
Adapter IP address
10.10.10.11
---------------------------------------------------------------------------
LABEL: TS_LOC_DOWN_ST
IDENTIFIER: 173C787F
Date/Time: Sun Nov 20 01:31:35 BEIST 2011
Sequence Number: xxx
Machine Id: 0000FACDD600
Node Id: xxx
Class: S
Type: INFO
Resource Name: topsvcs
Description
Possible malfunction on local adapter
Probable Causes
Local adapter mal-functioned
Local adapter lost connection to network
Local adapter mis-configured
Failure Causes
Local adapter mal-functioned
Local adapter lost connection to network
Local adapter mis-configured
Recommended Actions
Verify adapter configuration
Verify network connectivity
Detail Data
DETECTING MODULE
rsct,nim_control.C,1.39.1.18,4961
ERROR ID
6zV5DL.rTylC/oJc0A2.e.1...................
REFERENCE CODE
Adapter interface name
en3
Adapter offset
1
Adapter IP address
192.168.0.1
---------------------------------------------------------------------------
173C787F 1120013111 I S topsvcs Possible malfunction on local adapter
详细信息,这几台小机错误信息格式都是一样的,最先出现的是192.168.0 IP段的网卡错误,然后是对外访问IP的错误,信息如下:
---------------------------------------------------------------------------
LABEL: TS_LOC_DOWN_ST
IDENTIFIER: 173C787F
Date/Time: Sun Nov 20 01:31:35 BEIST 2011
Sequence Number: xxxx
Machine Id: 0000FACDD600
Node Id: xxxxx
Class: S
Type: INFO
Resource Name: topsvcs
Description
Possible malfunction on local adapter
Probable Causes
Local adapter mal-functioned
Local adapter lost connection to network
Local adapter mis-configured
Failure Causes
Local adapter mal-functioned
Local adapter lost connection to network
Local adapter mis-configured
Recommended Actions
Verify adapter configuration
Verify network connectivity
Detail Data
DETECTING MODULE
rsct,nim_control.C,1.39.1.18,4961
ERROR ID
6zV5DL.rTylC/ZDO1A2.e.1...................
REFERENCE CODE
Adapter interface name
en2
Adapter offset
0
Adapter IP address
10.10.10.11
---------------------------------------------------------------------------
LABEL: TS_LOC_DOWN_ST
IDENTIFIER: 173C787F
Date/Time: Sun Nov 20 01:31:35 BEIST 2011
Sequence Number: xxx
Machine Id: 0000FACDD600
Node Id: xxx
Class: S
Type: INFO
Resource Name: topsvcs
Description
Possible malfunction on local adapter
Probable Causes
Local adapter mal-functioned
Local adapter lost connection to network
Local adapter mis-configured
Failure Causes
Local adapter mal-functioned
Local adapter lost connection to network
Local adapter mis-configured
Recommended Actions
Verify adapter configuration
Verify network connectivity
Detail Data
DETECTING MODULE
rsct,nim_control.C,1.39.1.18,4961
ERROR ID
6zV5DL.rTylC/oJc0A2.e.1...................
REFERENCE CODE
Adapter interface name
en3
Adapter offset
1
Adapter IP address
192.168.0.1
---------------------------------------------------------------------------
作者: 东北胖子 发布时间: 2011-12-08
肯定是没经过培训就上岗的。。。。
作者: 老农 发布时间: 2011-12-08
肯定是没经过培训就上岗的。。。。
老农 发表于 2011-12-8 16:27
老农 发表于 2011-12-8 16:27
呵呵,您说对了。
作者: 东北胖子 发布时间: 2011-12-08